Find the R-value your climate calls for and how much insulation to buy to get there. Choose attic, walls, or floor, pick your state and climate zone, and the calculator shows ENERGY STAR's retrofit recommendation and the 2021 IECC new-home minimum. Enter what you already have, and it works out the R-value to add, the packages of batts or rolls from the coverage on the label, and — for attics — the bags of blown-in insulation from a manufacturer coverage chart you can override.
Sizing a heater or AC after the upgrade? Better insulation lowers the load, so rerun the BTU calculator. Finishing a basement or addition? The stud wall calculator and the drywall calculator cover the framing and board.
Frequently asked questions
What R-value do I need in my attic?
It depends on your climate zone. ENERGY STAR's retrofit recommendations, based on the 2021 IECC, call for R-30 in an uninsulated attic in zone 1 (south Florida, Hawaii), R-49 in zones 2 and 3, and R-60 in zones 4 through 8. If the attic already has 3–4 inches of insulation, the targets are R-25, R-38, and R-49 respectively. Pick your state to see which zones it spans, then choose your zone — zones follow county lines, so a single state can span three or more.
How many bags of blown-in insulation do I need?
Divide your attic area by 1,000 and multiply by the bags-per-1,000-sq-ft figure for the R-value you are adding, from the chart printed on the bag. As an example, Owens Corning's AttiCat blown-in fiberglass (27.5 lb bags) lists 14.6 bags per 1,000 sq ft for R-30, 19 for R-38, 25 for R-49, and 31.5 for R-60, with minimum depths of 10.75, 13.5, 17, and 20.5 inches. Cellulose is heavier and uses different numbers, so enter the figure from your product's chart to override ours.
How many batts or rolls of insulation do I need?
Divide the area by the coverage printed on the package and round up, adding about 5 % for trimming around blocking, wiring, and boxes. For example, a common R-19 package of eight 15×93 in batts covers 77.5 sq ft, so 1,000 sq ft of wall needs 14 packages with waste. Buy batts that match your framing: 15 in wide for studs or joists 16 in on center, 23 in wide for 24 in on center. Batts should fill the cavity without being compressed — squashing a batt lowers its R-value. If one layer of your batt falls short of the R-value you need to add, the calculator counts enough layers to reach it.
Can I add new insulation on top of old insulation?
Usually yes, as long as the old insulation is dry, free of mold or pests, and not vermiculite (which may contain asbestos — have it tested before disturbing it). R-values add together, so an attic with R-19 that needs R-49 needs about R-30 more. Lay new batts unfaced and perpendicular to the joists over the old layer, or blow loose fill over the top. Never add a second vapor retarder facing on top of an existing one, which can trap moisture.
What R-value do exterior walls need?
For new wood-frame homes, the 2021 IECC calls for R-13 in zones 1 and 2; R-20, or R-13 cavity plus R-5 of rigid foam sheathing, in zone 3; and R-30, or R-20 plus R-5 continuous insulation, or R-13 plus R-10, in zones 4 through 8. Existing 2×4 walls can hold R-13 to R-15 in the cavity and 2×6 walls R-19 to R-21, so reaching the new-home numbers in a retrofit usually means adding foam board when the siding is replaced.